Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 966
Filtrar
1.
ACS Biomater Sci Eng ; 10(4): 1966-1987, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38530973

RESUMO

A holistic biointegration of percutaneous bone-anchored metallic prostheses with both hard and soft tissues dictates their longevity in the human body. While titanium (Ti) has nearly solved osseointegration, soft tissue integration of percutaneous metallic prostheses is a perennial problem. Unlike the firm soft tissue sealing in biological percutaneous structures (fingernails and teeth), foreign body response of the skin to titanium (Ti) leads to inflammation, epidermal downgrowth and inferior peri-implant soft tissue sealing. This review discusses various implant surface treatments/texturing and coatings for osseointegration, soft tissue integration, and against bacterial attachment. While surface microroughness by SLA (sandblasting with large grit and acid etched) and porous calcium phosphate (CaP) coatings improve Ti osseointegration, smooth and textured titania nanopores, nanotubes, microgrooves, and biomolecular coatings encourage soft tissue attachment. However, the inferior peri-implant soft tissue sealing compared to natural teeth can lead to peri-implantitis. Toward this end, the application of smart multifunctional bioadhesives with strong adhesion to soft tissues, mechanical resilience, durability, antibacterial, and immunomodulatory properties for soft tissue attachment to metallic prostheses is proposed.


Assuntos
Peri-Implantite , Titânio , Humanos , Titânio/uso terapêutico , Próteses e Implantes , Osseointegração/fisiologia , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico
2.
Sci Rep ; 14(1): 3837, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360840

RESUMO

This study analyzed the migration of a calcar-guided short stem to determine the course of very early migration, as well as evaluated the effect of an additional calcium phosphate (CP) coating on a titanium plasma spray (TPS) coating, which has not been analyzed previously. Sixty patients were enrolled in this study and were treated with the A2 calcar-guided short stem. The implant coating was randomized with either the TPS or an additional CP coating, and radiostereometric analysis was performed with the baseline measurement before initial weight-bearing, along with follow-up examinations at 1 week, 6 weeks, 3 months, and 6 months. Implant migrations were 0.27 mm (standard deviation [SD], 0.13 mm) and 0.74 mm (SD, 1.11 mm) at 1 week and 6 months post-surgery, respectively, and 65% and 87% of the implants reached their final position 1 week and 6 weeks after surgery, respectively. After 6 weeks, 3 months, and 6 months, a significant increase was noted in the migration of the CP coating group vs. that of the TPS coating group. Upon the final observation at 6 months, the groups displayed on average a 0.74-mm migration. Most of the analyzed implants ceased migration within the first week post-surgery, but the CP coating demonstrated a higher and more prolonged migration compared to the TPS coating.


Assuntos
Fosfatos de Cálcio , Deambulação Precoce , Humanos , Próteses e Implantes , Titânio/uso terapêutico , Materiais Revestidos Biocompatíveis
3.
J Prosthet Dent ; 131(4): 742.e1-742.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383281

RESUMO

STATEMENT OF PROBLEM: To improve the osseointegration of dental implants and reduce microbiological growth, different micro- and nanoscale surface topographies can be used. PURPOSE: The purpose of this in vitro study was to evaluate the influence of Ti-6Al-4V with 4 surfaces, machined (DU), machined+hydroxyapatite (DUHAp), machined+acid-alkali treatment (DUAA), and additive manufacturing (DMA), on the physical, chemical, and microbiological properties. MATERIAL AND METHODS: The topography of Ti-6Al-4V disks with the 4 surfaces was evaluated by scanning electron microscopy (SEM), the chemical composition by energy dispersive X-ray spectroscopy (EDS), and the crystalline structure by X-ray diffraction (XRD). Physical and chemical properties were analyzed by using wettability and surface free energy, roughness, and microbial adhesion against Staphylococcus aureus by colony forming units (CFU). One-way ANOVA analysis of variance and the Tukey multiple comparisons test were applied to evaluate the data, except CFU, which was submitted to the Kruskal-Wallis nonparametric test (α=.05). RESULTS: DU photomicrographs showed a topography characteristic of a polished machined surface, DUHAp and DUAA exhibited patterns corresponding to the surface modifications performed, and in DMA the presence of partially fused spherical particles was observed. The EDS identified chemical elements inherent in the Ti-6Al-4V, and the DUHAp and DUAA disks also had the ions from the treatments applied. XRD patterns revealed similarities between DU and DMA, as well as characteristic peaks of hydroxyapatite (HA) in the DUHAp disk and the DUAA. Compared with DU and DMA the DUHAp and DUAA groups showed hydrophilic behavior with smaller contact angles and higher surface free energy (P<.05). DMA showed a higher mean value of roughness, different from the others (P<.05), and a higher CFU for S. aureus (P=.006). CONCLUSIONS: DUHAp and DUAA showed similar behaviors regarding wettability, surface free energy, and bacterial adhesion. Among the untreated groups, DMA exhibited higher roughness, bacterial adhesion, and lower wettability and surface free energy.


Assuntos
Ligas , Titânio , Titânio/uso terapêutico , Titânio/química , Staphylococcus aureus , Durapatita/uso terapêutico , Molhabilidade , Propriedades de Superfície , Microscopia Eletrônica de Varredura
4.
Rev Med Inst Mex Seguro Soc ; 61(Suppl 2): S193-S199, 2023 Sep 18.
Artigo em Espanhol | MEDLINE | ID: mdl-38011687

RESUMO

Background: The anterior cervical discectomy and fusion (ACDF) is the gold standard in the treatment of cervical compression pathology and the titanium cage for fusion represents the most used procedure at an institutional level. A technique using fibular autograft has been described, with good results, lower morbidity and lower cost. Objective: To compare the rate of fusion, subsidence and functional clinical results after discectomy with titanium cage and fibular autograft. Material and methods: A clinical trial with follow-up at 3 and 6 months was carried out in patients diagnosed with cervical spondylosis, candidates for ACDF. 2 groups were formed: fibular autograft and titanium cage. Pre and post functional evaluation using the cervical disability score was made, as well as radiographic fusion and subsidence evaluation. Descriptive statistics, Fisher's exact test, t-test and ANOVA were obtained, establishing p < 0.05. Results: A sample of 20 patients with an average age of 56 years was obtained, finding a fusion rate of 90% for fibular autograft and 30% for titanium (p = 0.02) at 3 months. 10% of patients with fibular autograft presented subsidence and 70% with titanium cage at 3 and 6 months (p = 0.02). In the functional results was not found difference between both procedures (p = 0.874). Conclusions: The use of autologous fibular graft offers a better rate of fusion and subsidence compared to the titanium cage, as well as similar functional results at 3 months of follow-up. It represents an excellent treatment option for cervical spondylosis.


Introducción: la disectomía cervical anterior y fusión (ACDF) es el estándar de oro en el tratamiento de la patología compresiva cervical. La caja de titanio para artrodesis es el procedimiento más usado a nivel institucional. Se ha descrito una técnica con autoinjerto de peroné, con buenos resultados, menor morbilidad y menor costo. Objetivo: comparar la tasa de fusión, subsidencia y resultados clínicos funcionales posteriores a disectomía con caja de titanio y autoinjerto de peroné. Material y métodos: ensayo clínico con seguimiento a tres y seis meses en pacientes con diagnóstico de espondilosis cervical, candidatos a ACDF. Se formaron dos grupos: autoinjerto de peroné y caja de titanio. Se hizo evaluación funcional antes y después mediante la escala de discapacidad cervical, y evaluación de fusión y subsidencia radiográficas. Se usó estadística descriptiva, prueba exacta de Fisher, prueba t y ANOVA, estableciendo una p < 0.05. Resultados: se obtuvo una muestra de 20 pacientes con promedio de 56 años; hubo una tasa de fusión del 90% para autoinjerto de peroné y 30% para titanio (p = 0.02) a los tres meses. De los pacientes con autoinjerto de peroné, 10% presentaron subsidencia y un 70% con caja de titanio a los tres y seis meses (p = 0.02). No se encontró diferencia en los resultados funcionales a tres y seis meses de ambos procedimientos. Conclusiones: el uso de injerto autólogo de peroné ofrece mejor tasa de fusión y subsidencia en comparación con la caja de titanio, así como resultados funcionales similares a los tres meses. Es una excelente opción para tratar la espondilosis cervical.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Espondilose , Titânio , Transplante Autólogo , Humanos , Pessoa de Meia-Idade , Autoenxertos , Vértebras Cervicais/cirurgia , Fíbula , Estudos Retrospectivos , Fusão Vertebral/métodos , Espondilose/cirurgia , Espondilose/tratamento farmacológico , Titânio/uso terapêutico , Resultado do Tratamento , Seguimentos
5.
Jt Dis Relat Surg ; 34(2): 289-297, 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37462631

RESUMO

OBJECTIVES: In this review, we discuss the efficacy and safety of biodegradable magnesium screws compared to titanium screws in the treatment of hallux valgus (HV) in patients undergoing distal metatarsal osteotomy (DMO). MATERIALS AND METHODS: Eligible scientific articles published prior to October 2022 were retrieved from the PubMed, Springer, ScienceDirect, and Cochrane Library databases. The terms used for searching included "hallux valgus", "distal metatarsal osteotomies", and "bioabsorbable magnesium screw" which were limited in the title or abstract through the text. The title and abstract were checked one by one to exclude the non-related studies. For primary identified studies and relevant systematic reviews, the full texts were accessed and browsed to finally include the eligible studies. No restriction was set on publication language and publication status. RESULTS: Two randomized-controlled trials (RCTs) and three non-RCTs that met the inclusion criteria were included. There was no significant difference in the American Orthopaedic Foot and Ankle Society (AOFAS) score, postoperative HV angle (HVA), intermetatarsal angle (IMA), Visual Analog Scale (VAS) score, soft tissue irritation, implant fracture, reoperation, and infection rates between two groups. CONCLUSION: Bioabsorbable magnesium compression screws show comparable clinical or radiological results to titanium compression screws in the treatment of HV in patients undergoing DMO.


Assuntos
Hallux Valgus , Hallux , Ossos do Metatarso , Humanos , Titânio/uso terapêutico , Magnésio , Resultado do Tratamento , Ossos do Metatarso/diagnóstico por imagem , Ossos do Metatarso/cirurgia , Implantes Absorvíveis , Hallux Valgus/diagnóstico por imagem , Hallux Valgus/cirurgia , Osteotomia/efeitos adversos , Osteotomia/métodos , Parafusos Ósseos/efeitos adversos
6.
ACS Biomater Sci Eng ; 9(8): 4442-4461, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37523241

RESUMO

Dental implants have become the mainstream strategy for oral restoration, and implant materials are the most important research hot spot in this field. So far, Ti implants dominate all kinds of implants. The surface properties of the Ti implant play decisive roles in osseointegration and antibacterial performance. Surface modifications can significantly change the surface micro/nanotopography and composition of Ti implants, which will effectively improve their hydrophilicity, mechanical properties, osseointegration performance, antibacterial performance, etc. These optimizations will thus improve implant success and service life. In this paper, the latest surface modification techniques of Ti dental implants are systematically and comprehensively reviewed. The various biomedical functionalities of surface modifications are discussed in-depth. Finally, a profound comment on the challenges and opportunities of this frontier is proposed, and the most promising directions for the future were explored.


Assuntos
Implantes Dentários , Titânio , Titânio/farmacologia , Titânio/uso terapêutico , Osseointegração , Propriedades de Superfície , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico
7.
Oper Neurosurg (Hagerstown) ; 25(4): 386-393, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37499255

RESUMO

BACKGROUND AND OBJECTIVES: The ability to maximize corpectomy cage endcap size and vertebral endplate coverage after corpectomy for lumbar burst fractures (L1-L5) is limited by the presence of lumbar nerve roots and the larger cross-sectional area of the lumbar endplates relative to the restrictive corridor for cage insertion. This work aims to provide details and clinical examples of a novel operative technique for 3-column reconstruction and stabilization of comminuted lumbar burst fractures. METHODS: Through a standard posterior midline approach and following posterior instrumentation and lateral extracavitary corpectomy, an in-situ assembly of a modular corpectomy cage that respects adjacent neural structures, restores segmental alignment, and maximizes endplate coverage across a lordotic segment is completed. RESULTS: Radiographic evidence of anatomic spinal reconstruction and stabilization with complete or near-complete endplate coverage without incurrence of new clinical deficit after this novel treatment of lumbar burst fractures. CONCLUSION: The fixation approach described in this report may be a valuable modification to a long-standing technique used for treating comminuted lumbar burst fractures (L1-L5) from a posterior-only approach without incurring additional neurological deficits and by improving endplate and apophyseal ring coverage.


Assuntos
Procedimentos de Cirurgia Plástica , Titânio , Humanos , Titânio/uso terapêutico , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia
8.
ACS Nano ; 17(12): 11290-11308, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37276377

RESUMO

Cancer phototheranostics have the potential for significantly improving the therapeutic effectiveness, as it can accurately diagnose and treat cancer. However, the current phototheranostic platforms leave much to be desired and are often limited by tumor hypoxia. Herein, a Schottky junction nanozyme has been established between a manganese-bridged cobalt-phthalocyanines complex and Ti3C2Tx MXene nanosheets (CoPc-Mn/Ti3C2Tx), which can serve as an integrative type I and II photosensitizer for enhancing cancer therapeutic efficacy via a photoacoustic imaging-guided multimodal chemodynamic/photothermal/photodynamic therapy strategy under near-infrared (808 nm) light irradiation. The Schottky junction not only possessed a narrow-bandgap, enhanced electron-hole separation ability and exhibited a potent redox potential but also enabled improved H2O2 and O2 supplying performances in vitro. Accordingly, the AS1411 aptamer-immobilized CoPc-Mn/Ti3C2Tx nanozyme illustrated high accuracy and excellent anticancer efficiency through a multimodal therapy strategy in in vitro and in vivo experiments. This work presents a valuable method for designing and constructing a multifunctional nanocatalytic medicine platform for synergistic cancer therapy of solid tumors.


Assuntos
Nanopartículas , Neoplasias , Fotoquimioterapia , Humanos , Fotoquimioterapia/métodos , Peróxido de Hidrogênio , Titânio/uso terapêutico , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Linhagem Celular Tumoral , Microambiente Tumoral , Nanopartículas/uso terapêutico
9.
Clin Oral Implants Res ; 34(7): 684-697, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37139538

RESUMO

OBJECTIVES: To study clinical and radiographic outcomes after non-surgical treatment of peri-implantitis using either an oscillating chitosan brush (OCB) or titanium curette (TC) and to observe changes in clinical signs of inflammation after repeated treatment. METHODS: Thirty-nine patients with dental implants (n = 39) presented with radiographic bone level (RBL) of 2-4 mm, bleeding index (BI) ≥ 2, and probing pocket depth (PPD) ≥ 4 mm were randomly assigned to mechanical debridement with OCB (test) or TC (control). Treatment was performed at baseline and repeated at 3, 6, and 9 months in cases with > 1 implant site with BI ≥ 1 and PPD≥4 mm. Blinded examiners recorded PPD, BI, pus, and plaque. The radiographic bone level change between baseline and 12 months was calculated. A multistate model was used to calculate transitions of BI. RESULTS: Thirty-one patients completed the study. Both groups exhibited a significant reduction in PPD, BI, and pus at 12 months compared to baseline. Radiographic analysis showed stable mean RBL in both groups at 12 months. There was no statistically significant difference in any of the parameters between the groups. CONCLUSIONS: Within the limitations of this 12-month multicenter randomized clinical trial, non-surgical treatment of peri-implantitis with OCB or TC showed no statistically significant differences between the groups. Clinical improvements and, in some cases, disease resolution, was observed in both groups. However, persistent inflammation was a common finding which further puts emphasis on the need for further treatment.


Assuntos
Quitosana , Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/diagnóstico por imagem , Peri-Implantite/terapia , Quitosana/uso terapêutico , Titânio/uso terapêutico , Seguimentos , Resultado do Tratamento , Inflamação , Supuração/induzido quimicamente , Implantes Dentários/efeitos adversos
10.
Curr Top Med Chem ; 23(19): 1835-1849, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37151173

RESUMO

Titanocene dichloride and budotitane have opened a new chapter in medicinal chemistry of titanium(IV) complexes being novel non-platinum antitumor metallic agents. Numerous efforts have led to the discovery of the diamino bis-phenolato titanium(IV) complexes. Among which, the [ONNO] and [ONON] type ligands namely Salan, Salen and Salalen coordinated titanium(IV) alkoxyl complexes have demonstrated significantly enhanced aqueous stability, their in vitro and in vivo antitumor efficacy, mechanism of action, structure-activity relationships and combined tumor therapy have been intensively investigated. Replacement of the labile alkoxyls with a second chelator resulted in structural rigid titanium(IV) complexes, which showed exceedingly good aqueous stability and potent antitumor activity both in vitro and in vivo. The unique ligand system successfully allowed the access of isotopic [45Ti]Titanium(IV) complexes, post-synthetic modification, facile synthetic protocols and antitumor congeneric zirconium(IV) and hafnium(IV) complexes. This review presents recent research progress in the field of antitumor group 4 metal complexes stabilized with phenolato ligands; especially their structure-activity relationships are summarized.


Assuntos
Antineoplásicos , Complexos de Coordenação , Neoplasias , Compostos Organometálicos , Humanos , Titânio/farmacologia , Titânio/química , Titânio/uso terapêutico , Ligantes , Neoplasias/tratamento farmacológico , Compostos Organometálicos/química , Compostos Organometálicos/farmacologia , Compostos Organometálicos/uso terapêutico , Relação Estrutura-Atividade , Antineoplásicos/química , Complexos de Coordenação/farmacologia
11.
J Hand Surg Asian Pac Vol ; 28(2): 292-296, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37120300

RESUMO

A 28-year-old man sustained a complex forearm injury from high-energy trauma, causing ulnar nerve injury, a bone defect, forearm malunion and synostosis. A 3D-printed titanium truss cage was used to solve these problems. This patient achieved union of the bone defect, was pain-free and had no recurrent synostosis 2 years after reconstructive surgery. The advantages of the 3D-printed titanium truss cage included anatomical fit, immediate mobilisation and low morbidity of the donor side of the bone graft. This study reported a promising result from using 3D-printed titanium truss cages to manage complex forearm bony problems. Level of Evidence: Level V (Therapeutic).


Assuntos
Traumatismos do Antebraço , Sinostose , Masculino , Humanos , Adulto , Titânio/uso terapêutico , Impressão Tridimensional , Próteses e Implantes , Traumatismos do Antebraço/complicações , Traumatismos do Antebraço/diagnóstico por imagem , Traumatismos do Antebraço/cirurgia
12.
Small Methods ; 7(8): e2300044, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075731

RESUMO

MXene QDs (MQDs) have been effectively used in several fields of biomedical research. Considering the role of hyperactivation of immune system in infectious diseases, especially in COVID-19, MQDs stand as a potential candidate as a nanotherapeutic against viral infections. However, the efficacy of MQDs against SARS-CoV-2 infection has not been tested yet. In this study, Ti3 C2 MQDs are synthesized and their potential in mitigating SARS-CoV-2 infection is investigated.  Physicochemical characterization suggests that MQDs are enriched with abundance of bioactive functional groups such as oxygen, hydrogen, fluorine, and chlorine groups as well as surface titanium oxides. The efficacy of MQDs is tested in VeroE6 cells infected with SARS-CoV-2. These data demonstrate that the treatment with MQDs is able to mitigate multiplication of virus particles, only at very low doses such as 0,15 µg mL-1 . Furthermore, to understand the mechanisms of MQD-mediated anti-COVID properties, global proteomics analysis are performed and determined differentially expressed proteins between MQD-treated and untreated cells. Data reveal that MQDs interfere with the viral life cycle through different mechanisms including the Ca2 + signaling pathway, IFN-α response, virus internalization, replication, and translation. These findings suggest that MQDs can be employed to develop future immunoengineering-based nanotherapeutics strategies against SARS-CoV-2 and other viral infections.


Assuntos
COVID-19 , Pontos Quânticos , Humanos , SARS-CoV-2 , Pontos Quânticos/química , Titânio/uso terapêutico , Titânio/química
13.
J Periodontol ; 94(9): 1122-1132, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37070363

RESUMO

BACKGROUND: Peri-implantitis is a frequent finding. Initial treatment involves non-surgical debridement of the implant surface. Recent studies have found a correlation between titanium (Ti) particle release and peri-implantitis, yet there is a dearth of information regarding the effect of various non-surgical instrumentation on particle release or peri-implantitis resolution. METHODS: Patients with peri-implantitis were recruited for a randomized, blinded, parallel-group clinical trial. The implants were randomized to treatment composed of Ti curettes ("Mech" group) or implant-specific treatment composed of rotary polymer microbrushes ("Imp" group). Ti release in submucosal peri-implant plaque pre- and 8 weeks posttreatment was assessed as the primary outcome. Peri-implant probing depth, bleeding on probing, and suppuration on probing were evaluated and compared between groups. RESULTS: Thirty-four participants completed treatment; 18 were randomized to the Mech group and 16 to the Imp group. The groups were comparable for Ti levels and probing depths at baseline. A trend was noted for 10-fold greater Ti dissolution in the Mech group posttreatment compared to the Imp group (p = 0.069). The Imp group had a significant reduction in probing depth posttreatment (p = 0.006), while the Mech group reduction was not significant. CONCLUSION: Peri-implantitis treated non-surgically with implant-specific instruments (Imp group) had a significantly greater decrease in probing depth versus the Mech treatment group. This improvement was linked with a trend for less Ti release to the peri-implant plaque by the non-abrasive treatment.


Assuntos
Implantes Dentários , Placa Dentária , Peri-Implantite , Humanos , Peri-Implantite/cirurgia , Peri-Implantite/tratamento farmacológico , Titânio/uso terapêutico , Placa Dentária/terapia , Resultado do Tratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-36744654

RESUMO

The use of cannulated screws and titanium plates to reinforce the sternal closure or to treat sternal dehiscence after median sternotomy has already been suggested in several articles. The system proposed here has some important advantages over those already described. Moreover, thanks to its characteristics, this system can also be used to treat pathologies affecting the entire rib cage. The system consists of a first threaded cannulated screw that is inserted in the bone or chondral cartilage and accommodates a cap screw that is tightened into the first screw and fixes a plate according to the following scheme: a threaded cannulated screw/plate/cap screw (Brixia system of screws). This system allows the plates to be fixed on the anterior face of the ribs and/or sternum without the need to enlarge dissection of the tissue, thereby lowering the danger of haemorrhage and injury to the thoracic organs. For this reason, it is particularly suitable for treating post-sternotomy sternal dehiscence, but it can be used to reinforce the primary sternal closure (after median or transversal sternotomy) in high-risk patients with sternal dehiscence. Owing to the modular nature of the system, singular components can also be utilized independently.


Assuntos
Cirurgia Torácica , Humanos , Titânio/uso terapêutico , Deiscência da Ferida Operatória/cirurgia , Esterno/cirurgia , Esternotomia , Parafusos Ósseos , Fios Ortopédicos
15.
BMC Oral Health ; 23(1): 32, 2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36658553

RESUMO

BACKGROUND AND OBJECTIVE: The emergence of peri-implant diseases has prompted various methods for decontaminating the implant surface. This study compared the effectiveness of three different approaches, chlorhexidine digluconate (CHX) combined with erbium-doped yttrium-aluminum-garnet (Er:YAG) laser, photodynamic therapy (PDT), and CHX only, for reducing biofilm vitality from implant-like titanium surfaces. STUDY DESIGN/MATERIALS AND METHODS: The study involved eight volunteers, each receiving a custom mouth device containing eight titanium discs. The volunteers were requested to wear the device for 72 h for biofilm development. Fluorescence microscopy was used to evaluate the remaining biofilm with a two-component nucleic acid dye kit. The vital residual biofilm was quantified as a percentage of the surface area using image analysis software. Sixty-four titanium discs were assigned randomly to one of four treatment groups. RESULTS: The percentage of titanium disc area covered by vital residual biofilm was 43.9% (7.7%), 32.2% (7.0%), 56.6% (3.6%), and 73.2% (7.8%) in the PDT, Er:YAG, CHX, and control groups, respectively (mean (SD)). Compared to the control group, the treatment groups showed significant differences in the area covered by residual biofilm (P < 0.001). CHX combined with Er:YAG laser treatment was superior to CHX combined with PDT, and CHX only was better than the control. CONCLUSION: Within the current in vitro model's limitations, CHX combined with Er:YAG laser treatment is a valid method to reduce biofilm vitality on titanium discs.


Assuntos
Implantes Dentários , Lasers de Estado Sólido , Fotoquimioterapia , Humanos , Antibacterianos , Lasers de Estado Sólido/uso terapêutico , Titânio/uso terapêutico , Érbio , Fotoquimioterapia/métodos , Biofilmes , Propriedades de Superfície , Implantes Dentários/microbiologia
16.
Medicina (Kaunas) ; 58(11)2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36363548

RESUMO

Background and objectives: Cementless total hip arthroplasty is a common surgical procedure and perioperative thromboprophylaxis is used to prevent deep vein thrombosis or pulmonary embolism. Osseointegration is important for long-term implant survival, and there is no research on the effect of different thromboprophylaxis agents on the process of osseointegration. Materials and Methods: Seventy rats were allocated as follows: Group I (control group), Group II (enoxaparin), Group III (nadroparin), and Group IV (fondaparinux). Ovariectomy was performed on all subjects, followed by the introduction of an intramedullary titanium implant into the femur. Thromboprophylaxis was administered accordingly to each treatment group for 35 days postoperatively. Results: Group I had statistically significantly lower anti-Xa levels compared to treatment groups. Micro-CT analysis showed that nadroparin had lower values compared to control in bone volume (0.12 vs. 0.21, p = 0.01) and percent bone volume (1.46 vs. 1.93, p = 0.047). The pull-out test showed statistically significant differences between the control group (8.81 N) compared to enoxaparin, nadroparin, and fondaparinux groups (4.53 N, 4 N and 4.07 N, respectively). Nadroparin had a lower histological cortical bone tissue and a higher width of fibrous tissue (27.49 µm and 86.9 µm) at the peri-implant area, compared to control (43.2 µm and 39.2 µm), enoxaparin (39.6 µm and 24 µm), and fondaparinux (36.2 µm and 32.7 µm). Conclusions: Short-term administration of enoxaparin, nadroparin, and fondaparinux can reduce the osseointegration of titanium implants, with nadroparin having the most negative effect. These results show that enoxaparin and fondaparinux are preferred to be administered due to a lesser negative impact on the initial implant fixation.


Assuntos
Nadroparina , Tromboembolia Venosa , Feminino , Ratos , Animais , Nadroparina/farmacologia , Nadroparina/uso terapêutico , Fondaparinux , Enoxaparina/farmacologia , Enoxaparina/uso terapêutico , Titânio/uso terapêutico , Osseointegração , Fator X , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Tromboembolia Venosa/tratamento farmacológico
17.
Biomater Adv ; 142: 213149, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36270158

RESUMO

Recent advances in coronary stents have all been distinctively focused towards directing re-endothelialization with minimal in-stent restenosis, potentially via alterations in surface topographical cues, for augmenting the efficacy of vascular implants. This perspective was proven by our group utilizing a simple and easily scalable nanosurface modification strategy on metallic stents devoid of any drugs or polymers. In the present work, we explore the impact of surface characteristics in modulating this cell response in-vitro and in-vivo, using titania coated cobalt-chromium (CC) stents, with and without nanotopography, in comparison to commercial controls. Interestingly, titania nanotopography facilitated a preferential cell response in-vitro as against the titania coated and bare CC surfaces, which can be attributed to surface topography, hydrophilicity, and roughness. This in turn altered the cellular adhesion, proliferation and focal contact formations of endothelial and smooth muscle cells. We also demonstrate that titania nanotexturing plays a pivotal role in fostering rapid re-endothelialization with minimal neointimal hyperplasia, leading to excellent in-vivo patency of CC stents post 8 weeks implantation in rabbit iliac arteries, in comparison to bare CC, nano-less titania coated CC, and commercial drug-eluting stents (CC DES), without administering antiplatelet agents. This exciting result for the drug and polymer-free titania nanotextured stents, in the absence of platelet therapy, reveals the possibility of proposing an alternative to clinical DES for coronary stenting.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Animais , Coelhos , Reestenose Coronária/prevenção & controle , Stents , Stents Farmacológicos/efeitos adversos , Titânio/uso terapêutico , Polímeros
18.
Nano Lett ; 22(20): 8321-8330, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36222477

RESUMO

Ti3C2-MXene-based composites provide multifunctional interfaces in diagnosis and treatment of tumors. Herein, we proposed a multifunctional nanoplatform based on Ti3C2-MXene-Au nanocomposites, which combines photothermal properties and peroxidase-like activity, accomplishing synergistic photothermal therapy (PTT) and enzyme dynamic therapy (EDT) accompanied by photoacoustic (PA) and thermal dual-mode imaging in vivo. Furthermore, PTT induces immunogenic cell death, and EDT promotes cell apoptosis, facilitating dendritic cell (DC) maturation and T cell infiltration into the tumor. On this basis, the antibody OX40 (αOX40) was utilized to further contribute immune therapy for reversing the immunosuppressive tumor microenvironment by activating CD4+ and CD8+ T cells. In summary, a triune of PTT/EDT/antitumor immune therapy is achieved by combining Ti3C2-MXene-Au nanocomposites and αOX40, which possesses several strong features of good biocompatibility, NIR-controlled targeting, significant cancer cell killing, and satisfactory biosafety in vitro and in vivo. Our work might highlight the promising application of MXene-based nanoplatforms for cancer therapy.


Assuntos
Nanocompostos , Nanopartículas , Neoplasias , Humanos , Terapia Fototérmica , Titânio/uso terapêutico , Linfócitos T CD8-Positivos , Nanocompostos/uso terapêutico , Peroxidases , Fototerapia , Linhagem Celular Tumoral , Microambiente Tumoral
19.
BMJ Case Rep ; 15(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36135998

RESUMO

The role of surgery for metastases to the vertebra from yolk sac tumours has not been established. The main treatment for disseminated disease is chemotherapy. We present a man in his 30s with a left orchiectomy for a testicular mixed germ cell tumour with a prominent yolk sac component who, 12 months later, developed an asymptomatic metastasis to the L2 vertebra unresponsive to chemotherapy and radiotherapy. The patient underwent resection of the L2 vertebral body, leaving a small residual tumour anterior to the vertebra attached to the great vessels. Pathology confirmed the diagnosis of a metastatic testicular yolk sac tumour in the vertebra. The postoperative MRI 6 months later demonstrated significant expansion of the tumour at the soft tissues anterior to the expandable titanium cage encasing the great vessels and extending to the paraspinal areas. Additional salvage surgery was not recommended because of the advanced stage of the tumour.


Assuntos
Tumor do Seio Endodérmico , Neoplasias Embrionárias de Células Germinativas , Neoplasias Testiculares , Tumor do Seio Endodérmico/diagnóstico por imagem , Tumor do Seio Endodérmico/cirurgia , Humanos , Masculino , Neoplasias Embrionárias de Células Germinativas/diagnóstico por imagem , Neoplasias Embrionárias de Células Germinativas/cirurgia , Orquiectomia , Coluna Vertebral/patologia , Neoplasias Testiculares/diagnóstico por imagem , Neoplasias Testiculares/tratamento farmacológico , Neoplasias Testiculares/cirurgia , Titânio/uso terapêutico
20.
World Neurosurg ; 166: e155-e162, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35803562

RESUMO

BACKGROUND: Dorsal instrumentation and decompression are the mainstays of spinal tumor treatment. Replacing titanium screws with carbon fiber-reinforced polyetheretherketone (CFRP) screws can reduce imaging artifacts on neural structures and perturbations of radiation dose. Further reduction of metal content in such screws might enhance the benefit. The aim of this study was to assess the artifacts produced by all-titanium screws (Ti-Ti), CFRP thread-titanium screw heads (C-Ti), and all-CFRP screws (C-C). METHODS: A cadaveric spine was used to place Ti-Ti, C-Ti, and C-C consecutively from T2 to S1. Computed tomography and 1.5T and 3T magnetic resonance imaging were performed for each screw system. Axial T1- and T2-weighted sequences of representative thoracic and lumbar regions were assessed for artifacts. The artifacts were classified as not relevant, considerable, or severe. RESULTS: We evaluated 92 screws and made 178 artifact assessments. The artifacts were clearly visible in computed tomography scans but did not influence the visualization of intraspinal structures. Severe magnetic resonance imaging artifacts were found in 28% (17/60, mostly in the thoracic spine) of Ti-Ti, 2% (1/60, all T1 sequences) of C-Ti, and 0% of C-C, and considerable artifacts were found in 47% (28/60) of Ti-Ti, 10% (6/60, only 1 T2 sequence) of C-Ti, and 0% of C-C screws (P < 0.001). CONCLUSIONS: CFRP pedicle screws reduced the artifact intensity in spinal structures compared with titanium screws, and may be beneficial for planning radiotherapy and for follow-up imaging. C-C demonstrated an enhanced effect on dorsal structures.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Artefatos , Benzofenonas , Cadáver , Fibra de Carbono , Humanos , Cetonas , Vértebras Lombares/cirurgia , Plásticos , Polietilenoglicóis , Polímeros , Fusão Vertebral/métodos , Titânio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...